Phone
Address
ZhengZhou (HQ), Shenzhen (R&D Center), Suzhou (R&D Center), China
MicroStacker™ Polymer Detection System is a biotin-free, polymeric horseradish peroxidase (HRP)- secondary antibody conjugate system for the detection of mouse and rabbit primary antibody on formalin-fixed, paraffin-embedded (FFPE) tissues in an immunohistochemistry (IHC) procedure. The innovative MicroStacker™ technology allows well-controlled layered stacking of antibodies and peroxidase enzymes on a micro-polymer scaffold. This technique results in a compact polymeric structure that easily penetrates to all cellular compartments. Plus, the system utilizes F(ab’) fragments of IgG secondary antibody instead of the whole IgG, which avoids the background caused by non-specific binding of whole IgG to endogenous Fc receptors. According to your needs, the linker (mouse/rabbit) can be flexibly selected to further improve the staining effect. MicroStacker™ Flex HRP-polymer detection kit (mouse/rabbit linker) can be commonly used for detection of murine and rabbit antibodies. The Flex kit is suitable for various types of automatic immunohistochemistry stainer.
Powered by innovative MicroStacker™ technology, this system enables controlled layered stacking of antibodies and peroxidase enzymes on a micro-polymer scaffold. The result? A compact polymeric structure that effortlessly permeates all cellular compartments, ensuring comprehensive staining coverage.
Notably, our system utilizes F(ab’) fragments of IgG secondary antibodies, mitigating background noise caused by non-specific binding of whole IgG to endogenous Fc receptors. By upgrading the degree of polymerization of enzymes and antibodies, we achieve heightened sensitivity for optimal detection.
Compatible with various automatic immunohistochemistry stainers, our MicroStacker™ Plus HRP-polymer detection kit delivers consistent and reliable results across mouse and rabbit primary antibodies. Elevate your IHC workflow with precision and efficiency using the MicroStacker™ Polymer Detection System.
The innovative MicroStackerTM technology allows for the orientation-controlled attachment of Fab’ fragments of IgG on the poly-HRP core based on micro-polymer scaffolds.
The proprietary Fab’ labeling methods avoids the occasional blocking of the antibody binding site during the bioconjugation process, thus increase the sensitivity of the polymer. The compact polymeric structure easily penetrates to all cellular compartments, which provides consistent results in all types of nuclear, cytoplasmic and membranous antigens. The overall effect is superior sensitivity compared to other conventional HRP polymers with bulky dextran backbones.
Biotin-free detection eliminates background staining due to endogenous biotin. Plus, the system utilizes Fab’ fragments instead of the whole IgG, which avoids the background caused by non-specific binding of the whole IgG to the endogenous Fc receptor.
Product Name |
|
Format |
Components |
Specification |
MicroStackerTM Flex HRP-Polymer Detection Kit |
SD5100
|
V1
|
Peroxidase Blocking Reagents |
30ml*1 |
Linker, Rabbit-anti-Mouse |
30ml*1 |
|||
Anti-Rabbit HRP-Polymer |
30ml*1 (300T) |
|||
SD5300
|
V2
|
20*DAB Chromogen |
2.4ml*1 |
|
DAB Substrate Buffer |
30ml*2 |
|||
Hematoxylin |
30ml*1 |
Stainer Type:CNT330
Primary antibody incubation: RT, 30min
Linker: RT, 20min
Secondary antibody incubation: RT, 20min
DAB incubation: 5min
MicroStackerTM Flex (Mouse Linker)
EnVision Flex+, Mouse Linker
Lymphoma (Ki67 mouse monoclonal antibody)
EnVision Flex+
MicroStackerTM FLex